The below post explains the end to end process of software updates management in SCCM 2012 Pre-requisites: 1. WSUS Server (WSUS 3.0 SP2 ) should be installed on the SCCM site server or if you want to install WSUS on another server, it is important that you install WSUS administration console as the SCCM Server uses API. This link explains the step by step procedure to install WSUS 3.0 SP2 2. Install SUP-Software Update Point on the SCCM Server . 3. Reporting Services Point: Install reporting services point role as described in this link . 4. Client agent: The software update client agent should be enabled(will be enabled by default) and the settings have to specified as per the requirement. On SCCM console, go to Administration>Site Configuration>Client settings>Right click on Default client settings> Click on Properties. If required, we can create custom client settings and then enable client settings for that settings. ...
This post explains on how to extend the schema for SCCM 2007.
Requirements:
* Schema Admin Group member or equivalent access
* Extadch.exe file located in the SMSSETUP/BIN/I386
Reference : http://technet.microsoft.com/en-in/library/bb680608.aspx
1. Back up schema master role to avoid any implications
2. Login with Schema admin group user member or equivalent role user.
3. Run extadch.exe file from SMSSETUP/BIN/I386
4.Verify whether the execution is successful by checking the extadch.log file that will be created in the root directory of the system where it has been run.
It will create 4 classes and 14 attributes in the schema as shown.
The most common error will be error code 5 i.e. access denied, check the permissions and run the file again.
However, this is not the recommended method to extend schema but using LDIF file available in the same directory is.
Requirements:
* Schema Admin Group member or equivalent access
* Extadch.exe file located in the SMSSETUP/BIN/I386
Reference : http://technet.microsoft.com/en-in/library/bb680608.aspx
1. Back up schema master role to avoid any implications
2. Login with Schema admin group user member or equivalent role user.
3. Run extadch.exe file from SMSSETUP/BIN/I386
4.Verify whether the execution is successful by checking the extadch.log file that will be created in the root directory of the system where it has been run.
It will create 4 classes and 14 attributes in the schema as shown.
The most common error will be error code 5 i.e. access denied, check the permissions and run the file again.
However, this is not the recommended method to extend schema but using LDIF file available in the same directory is.
Comments